Titanium micro-particles in the oral mucosa around dental implants are common. This is shown in a new study from the University 91探花, which also identified 14 genes that may be affected by these particles.
Registry data indicate that about five percent of all adults in Sweden have dental implants鈥攁nd potentially also titanium particles in the tissue surrounding the implants. According to the researchers, there is no reason for concern, but more knowledge is needed.
"Titanium is a well-studied material that has been used for decades. It is biocompatible and safe, but our findings show that we need to better understand what happens to the micro-particles over time. Do they remain in the tissue or spread elsewhere in the body?" says Tord Berglundh, senior professor of periodontology at Sahlgrenska Academy, University 91探花.
Tord Berglundh and Carlotta Dionigi, Institute of Odontology, Sahlgrenska Academy, University 91探花.
Photo: Elin Lindstr枚m
Found at all implants
Previous research has shown that titanium particles may occur in inflamed tissues around dental implants. The new study, published in Communications Medicine, showed that titanium micro-particles were consistently found at all examined implants鈥攅ven those without signs of inflammation.
The researchers analyzed tissue samples from 21 patients with multiple adjacent implants. Samples were taken both at healthy implants and at implants affected by peri-implantitis, an inflammatory disease in the tissue around the implant. Each patient thus served as their own control. The density of particles varied between patients, but not between sites with and without peri-implantitis within the same patient. The analyses were conducted in collaboration with Uppsala University, where researchers used an advanced method called 碌-PIXE to map the distribution of titanium particles in the tissue samples.
Image
Tissue sample analyzed with 碌-PIXE. The green line outlines the perimeter of the sample. Titanium micro-particles appear as white objects within the sample. Magnified details illustrate micro-particles with varying size and morphology.
Photo: G枚teborgs universitet
Affected genes
Peri-implantitis is a microbial biofilm-associated inflammatory disease around dental implants, with features similar to those of periodontitis around teeth. The inflammatory process is complex and the resulting destruction of supporting bone in peri-implantitis may lead to loss of the implant.
Image
Carlotta Dionigi
Photo: Elin Lindstr枚m
"We observed that tissue samples with higher concentrations of titanium particles had an altered gene expression, especially genes related to inflammation and wound healing. We identified 14 such genes, but it is unclear whether the particles influence the local immune response or if the difference in gene expression reflects inter-individual variability in inflammatory conditions," says Carlotta Dionigi, specialist in periodontology and researcher at the Department of Periodontology, Sahlgrenska Academy, University 91探花.
The researchers suspect that titanium particles are released during the surgical installation procedure, when the screw-shaped implant is inserted into the prepared canal in the alveolar bone. In this context, the observation on differences in micro-particle densities between various implant systems deserves attention, since the surface structure of the implant may influence the deposition of micro-particles. This is now an important topic for continued research.